Bathroom Fan Not Clearing the Steam
The shower is over. The mirror is still a cloud. The ceiling is damp. You can hear a fan, or you think you can, and the steam does not care. A fan that does not clear steam is not a small style problem. That moisture leaves the bathroom and looks for a cool wall, a closet, or the attic if the duct was never finished.
Start with the simplest proof. Turn the fan on. Hold a single square of toilet tissue against the grille. It should cling. If it falls, the fan is not pulling, no matter how proud the switch looks. Dust packed into the grille can weaken a fan that is otherwise fine. Power off at the breaker if you are going to remove the cover, and do not tug on wiring you do not understand. A cover that pops off for a wipe is enough for most people. If the housing is loose, noisy in a new way, or you see damaged wire, stop and call an electrician.
If the tissue clings and the room still will not clear, the air may be going nowhere useful. The duct is supposed to end outdoors, through a roof cap or a wall cap with a damper that can open. A duct lying in the attic insulation, or blowing into the attic "because the attic is vented," dumps shower water into the wood. You can sometimes see this from the attic hatch with a flashlight, standing on the framing, not on the drywall. If you are not safe up there, a handy person or an HVAC tech can confirm the termination in a short visit. That visit is cheaper than wet insulation.
Run time is the other half. A fan that works still loses if you shut it off the second the water stops. Run it during the shower and for 20 to 30 minutes after. Leave the bathroom door open once the room has cleared so the last damp air is not trapped, and so you are not relying on a closed door to hide a weak fan. A timer switch helps if everyone in the house forgets. The timer is not a repair for a fan that fails the tissue test.
Makeup air matters in a tight room. If the door is shut, the window is shut, and the fan is trying to pull, it may not have air to pull. Crack the door an inch during the shower as a test. If the tissue suddenly clings and the mirror clears, the fan was starved. A small gap under the door is the usual fix, not a bigger fan you have not tested.
Steam that only happens when the house humidity is already high will clear slower. A gauge in the hall tells you if the whole house is damp and the bathroom is the last straw. Fixing a fan still helps. It is not a substitute for a wet crawl space.
Do not vent a fan into a soffit by guesswork, and do not disconnect it because it is loud. Loud and effective is better than quiet and fake, though a fan can be both loud and useless if the duct is crushed. Look at the path.
Write two results: tissue clings or falls, and whether you can see the duct ending outdoors. Those two facts decide the next step.
If someone in the house is getting worse, that is a doctor conversation, and opening walls or the furnace cabinet is a job for a licensed pro.
The tissue test and the duct path are pictured in When Your House Doesn't Feel Right. ClearNest, $2.99, at https://clearnestair.com/book.